SOFAR 3.3k~12kTL-X SOLAR INVERTER
3300/4400/5000/5500/6600/8800/11000/12000
Three-Phase Dual-MPPT
Integrated with DC Switch
Max. efficiency up to 98.3%
Super large 4-inch LCD
Built-in DRM port and logic
Smart Monitoring, RS485, WIFI / Ethernet / GPRS (Optional)
Over / Under Voltage, Over Current, Over Temperature, Anti-Is landing And Other Multiple Protections
Datasheet | SOFAR 3.3KTL-X |
SOFAR 4.4KTL-X |
SOFAR 5KTL-X (Australia) |
SOFAR 5.5KTL-X |
SOFAR 6.6KTL-X |
SOFAR 8.8KTL-X |
SOFAR 11KTL-X |
SOFAR 12KTL-X |
Input (DC) | ||||||||
Recommended Max. PV input power | 4390Wp | 5860Wp | 6650Wp | 7320Wp | 8780Wp | 11710Wp | 14630Wp | 15960Wp |
Max DC power for single MPPT | 3550W | 4500W | 5700W | 5700W | 6250W | 6200W | 6200W | 6850W |
Number of MPP trackers | 2 | |||||||
Number of DC inputs | 1/1 | 2/1 | ||||||
Max. Input voltage | 600V | |||||||
Start-up voltage | 120V | |||||||
Rated input voltage | 360V | |||||||
MPPT operating voltage range | 90-580V | |||||||
Full power MPPT voltage range | 160V-850V | 190V-850V | 240V-850V | 240V-850V | 290V-850V | 380V-850V | 480V-850V | 575V-850V |
Max. Input current per MPPT | 11A/11A | |||||||
Maxnimun DC input short circuit current per MPPT | 14A | |||||||
Output (AC) | ||||||||
Rated power | 3000W | 3680W | 5000W | 5000W | 6000W | 8000W | 10000W | 12000W |
Max. AC power | 3300VA | 4400VA | 5000VA | 5500VA | 6600VA | 8800VA | 11000VA | 13200VA |
Max. Output current | 4.8A | 6.4A | 8.0A | 8.0A | 9.6A | 12.8A | 15.9A | 19.1A |
Nominal grid voltage | L/N/PE, 220Vac, 230Vac, 240Vac | |||||||
Grid voltage range | 180Vac-276Vac (According to local standard) | |||||||
Nominal frequency | 50Hz/60Hz | |||||||
Grid frequency range | 45Hz-55Hz/54Hz-66Hz (According to local standard) | |||||||
Active power adjustable range | 0~100% | |||||||
THDi | <3% | |||||||
Power factor | 1default (adjustable+/-0. 8) | |||||||
Power limit export | Zero export or adjustable power limit export | |||||||
Performance | ||||||||
Max efficiency | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.3% | 98.3% | 98.3% |
European weighted efficiency | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% | 98.0% | 98.0% | 98.0% |
Self-consumption at night | <1W | |||||||
MPPT efficiency | >99.9% | |||||||
Protection | ||||||||
DC reverse polarity protection | Yes | |||||||
DC switch | Yes | |||||||
Safety protection | Anti islanding, RCMU, Ground fault monitoring | |||||||
ARPC | Anti reverse power controller(optional) | |||||||
Communication | ||||||||
Power management unit | According to certification and request | |||||||
Standard communication mode | RS485, Wifi/Ethernet/GPRS(optional), SD card | |||||||
Operation data storage | 25 years | |||||||
General Data | ||||||||
Ambient temperature range | -25℃~+60℃ | |||||||
Topology | Transformerless | |||||||
Degree of protection | IP65 | |||||||
Allowable relative humidity range | 0~100% | |||||||
Max. Operating altitude | 2000m | |||||||
Noise | <29dB | |||||||
Weight | 21kg | 21kg | 21kg | 21kg | 21kg | 22kg | 22kg | 22kg |
Cooling | Natural | |||||||
Dimension | 457*452*202mm | |||||||
Display | LCD display | |||||||
Warranty | 5 years/ 7 years/ 10 years | |||||||
Standard | ||||||||
EMC | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 | |||||||
Safety standards | IEC62109-1/2, IEC62116, IEC61727, IEC-61683, IEC60068(1,2,14,30), IEC60255 | |||||||
Grid standards | AS/NZS 4777, VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21, EN50549, G83, Rd1699, UTE C15-712-1, EN50530, NB/T32004 |